ASTM B167 Inconel 601 UNS N06601 Seamless Pipe and Tube

Inconel 601 pipe and tube combines a nickel-chromium base with controlled aluminum to provide strong resistance to high-temperature oxidation. We supply UNS N06601 / 2.4851 seamless pipe and tube to ASTM B167, heat-exchanger tubing to ASTM B163 or ASTM B516, and electric-fusion-welded pipe to ASTM B474/B474M when the project requires a larger fabricated size.
For a usable quotation, send the manufacturing route, outside diameter, wall thickness, length, quantity, heat-treatment condition, end preparation, inspection and certificate requirements.
Inconel 601 Pipe and Tube Procurement Overview
| Material | Inconel 601 / Alloy 601 / UNS N06601 / 2.4851 |
|---|---|
| Primary product | Seamless round pipe and tube; heat-exchanger tube; electric-fusion-welded pipe by project |
| Normal supply range | OD 6-219 mm, wall thickness 0.5-30 mm, straight length up to 12 m; larger welded sizes and other dimensions by enquiry |
| Condition | Annealed / solution annealed as required by the applicable product specification |
| Surface | Pickled, bright annealed or polished, selected according to service and fabrication requirements |
| Ends | Plain, square-cut or beveled; other end preparation to drawing |
| Documentation | EN 10204 3.1 MTC and specified inspection records can be arranged when included in the purchase order |
Choose the Correct Standard and Product Form
| Product form | Applicable standard | Buyer note |
|---|---|---|
| Seamless pipe and tube | ASTM B167 / ASME SB167 | Primary specification for UNS N06601 seamless pipe and tube for corrosion- and heat-resistant service. |
| Seamless condenser / heat-exchanger tube | ASTM B163 / ASME SB163 | For annealed heat-exchanger tubing. ASTM scope covers OD up to 76.2 mm within its stated wall limits. |
| Welded boiler / heat-exchanger tube | ASTM B516 / ASME SB516 | For welded UNS N06601 tube. ASTM scope covers OD 3.18-127 mm and wall 0.38-12.70 mm, while allowing other compliant dimensions. |
| Electric-fusion-welded pipe | ASTM B474/B474M | Use for fabricated welded nickel-alloy pipe when the project calls for this manufacturing route. |
| General seamless requirements | ASTM B829 | Companion requirements for seamless nickel-alloy pipe and tube; the product specification takes precedence if requirements conflict. |
Important: ASTM B517 welded pipe does not list UNS N06601, so it should not be specified for Alloy 601.
Product Forms and Available Processing
Seamless tube for high-temperature or corrosion-resistant service.
Round seamless pipe supplied by OD, wall thickness and length.
Fabricated welded pipe for projects specifying the applicable welded-pipe standard.
Heat-exchanger tube to a product-specific tube standard.
Welded boiler or heat-exchanger tube to ASTM B516 when specified.
Cut lengths, end preparation and surface finish can be matched to the order.
Why Select Alloy 601?
The chromium-aluminum combination promotes a protective oxide scale in elevated-temperature service.
Alloy 601 is commonly considered for furnace and heating equipment that repeatedly heats and cools.
Projects can specify seamless pipe, seamless heat-exchanger tube, welded heat-exchanger tube or fabricated welded pipe under the correct standard.
Inconel 601 Chemical Composition
| Element | Content, % | Element | Content, % |
|---|---|---|---|
| Nickel | 58.0-63.0 | Chromium | 21.0-25.0 |
| Iron | Remainder | Aluminum | 1.0-1.7 |
| Carbon | 0.10 max | Manganese | 1.0 max |
| Silicon | 0.50 max | Copper | 1.0 max |
| Sulfur | 0.015 max |
The aluminum addition is a defining selection feature of Alloy 601 and should not be omitted from the material table.
Typical Physical Properties
| Property | Typical value for annealed material |
|---|---|
| Density | 8.11 g/cm3 |
| Melting range | 1360-1411 C |
| Specific heat at room temperature | 448 J/kg-C |
| Thermal conductivity at room temperature | 11.2 W/m-C |
| Electrical resistivity at room temperature | 1.19 micro-ohm-m |
These are typical reference values, not purchase-order acceptance values. Required mechanical properties and tests should be taken from the selected product specification and agreed condition.
Inconel 601 vs Inconel 600 for Pipe Selection
| Selection factor | Inconel 601 | Inconel 600 |
|---|---|---|
| Key chemistry difference | Higher chromium with a deliberate aluminum addition | Higher nickel and no comparable aluminum requirement |
| Typical reason to choose | High-temperature oxidation and thermal-cycling duty | General high-temperature and corrosion-resistant service where Alloy 601's oxidation behavior is not required |
| Buyer action | Confirm the actual atmosphere, operating temperature, thermal cycle, pressure and fabrication route before substitution. | |
Typical Applications
Inspection, Testing and Documents
Inspection scope is agreed against the selected product standard and purchase order. Available order options may include chemical analysis, tensile testing, hydrostatic or nondestructive electric testing, dimensional inspection, PMI, surface inspection and third-party witnessing. State the required acceptance standard, certificate type and witness point in the enquiry.
No test result or third-party certificate is implied until it is included in the order and supported by the supplied documents.
Packing for Inconel 601 Pipe and Tube
Pipe and tube can be protected with end caps, waterproof wrapping, bundled supports, wooden cases or export frames according to dimensions, surface condition and transport method.



Ordering Checklist
| Material and standard | UNS N06601 plus ASTM/ASME product specification and edition |
|---|---|
| Product form | Seamless pipe, seamless heat-exchanger tube, welded heat-exchanger tube or electric-fusion-welded pipe |
| Dimensions | OD or NPS, wall thickness or schedule, length and quantity |
| Condition and surface | Annealing requirement, pickled/bright/polished finish and tolerances |
| Testing | Pressure/NDE method, PMI, dimensional inspection and witness requirements |
| Documents and logistics | MTC type, inspection reports, marking, packing and delivery destination |
Frequently Asked Questions
What ASTM standard covers Inconel 601 seamless pipe and tube?
ASTM B167 covers UNS N06601 seamless pipe and tube. ASTM B829 provides general requirements used with the listed seamless nickel-alloy product specifications.
Can ASTM B516 be used for Alloy 601 pipe?
ASTM B516 is for welded boiler, heat-exchanger and condenser tubes, not general welded pipe. Electric-fusion-welded Alloy 601 pipe can be specified under ASTM B474/B474M when that construction suits the project.
Is ASTM B517 suitable for UNS N06601?
No. The current ASTM B517 scope does not list UNS N06601. Specify the manufacturing route first, then select ASTM B167, B163, B516 or B474/B474M as applicable.
What information is needed to quote Inconel 601 pipe?
Provide the material designation, manufacturing route, standard and edition, OD or NPS, wall or schedule, length, quantity, heat-treatment condition, finish, testing, certificate, end preparation and packing requirements.
Why is Inconel 601 selected instead of Inconel 600?
Alloy 601 contains more chromium and a controlled aluminum addition, making it a stronger candidate for high-temperature oxidation and thermal-cycling service. Final selection still depends on atmosphere, temperature, pressure and fabrication requirements.